HPE PL DL385g10 Plus v2 AMD Epyc 7313 (3.0G/16C) 1x32G MR416i-a/4G 8SFF ocp 2x10GT 1x800W L9
HPE PL DL385g10 Plus v2 AMD Epyc 7313 (3.0G/16C) 1x32G MR416i-a/4G 8SFF ocp 2x10GT 1x800W L9
The HPE ProLiant DL385 Gen10 Plus v2 Server is redefining price/performance with the new math for virtualized compute. Powered by the latest AMD® EPYC® 7003 Series Processors , the HPE ProLiant DL385 Gen10 Plus v2 Server offers greater processing power, memory speeds up to 3200 MT/s. and data transfer rates with PCIe Gen4 capabilities. This 2P, 2U server has been designed with flexibility while delivering a high core count and large memory footprint. Choose this purpose-built platform for virtualization, High Performance Compute and memory centric workloads.
HPE PL DL385g10 Plus v2 Epyc 7313 (2.9G/16C) 1x32G MR416i-a/4G 8SFF 1x800W L9 2x10GTocp EIR
SKU Number | P55284-421 |
Model Name | HPE ProLiant DL385 Gen10 Plus v2 7313 3.0GHz 16-core 1P 32GB-R MR416i-a 8SFF 800W PS EU Server |
Processor | 7313 (16-Core, 3.0 GHz, 155W) |
Number of Processors | One processor |
Memory | 32 GB RDIMM DR 3200 MT/s (1x 32 GB) |
Network Controller | BCM 57416 10GbE 2p BASE-T OCP3 Adptr plus choice of standup card |
Storage Controller | MR416i-a Notes: Supports Tri-mode. |
Hard Drive | None ship as standard |
Internal Storage | 8 SFF Chassis (upgradeable to 24 SFF front + 8 SFF mid + 4SFF rear) |
Optical Drive Bay | Optional |
Optical Drive | None ship as standard |
PCI-Express Slots | 3-slots (x8, x16, x8) as standard |
Power Supply | 1x 800W HPE FlexSlot Power Supply Notes: EU Lot-9 compliant. |
Fans | 4-standard fans |
Management | Default: HPE iLO Standard with Intelligent Provisioning, HPE OneView Standard (requires download) |
Energy Star | 3.0 certified |
Form Factor | 2U Rack, SFF Easy Install rails without CMA |
Warranty | 3-year parts, 3-year labor, 3-year onsite support with next business day response. |
Platform Information Form Factor
|
Chassis Types
Notes: - DL385 Gen10 Plus v2 uses Basic Carrier drive cages, not Smart Carrier drive cages as used on DL385 Gen10 Plus. - The 4 LFF rear drive box will consume space for the primary and secondary riser. - The 8 and 12 LFF chassis also supports the 2 SFF rear drive box which allows for the user to attach a secondary or tertiary riser. - The 24 SFF chassis already supports 3x 8 SFF SAS/SATA drive cage kits - The 8 NVMe U.3 or U.2 cage kits (P27194-B21, P26931-B21, P26932-B21) can only be leveraged in the SFF chassis and replaces Box 1, 2 or 3. - The Universal Media Bay (P14609-B21) not available with the LFF chassis or the 24 SFF front, and can only be populated in Box 1. - The 8 NVMe SFF can be upgraded with additional two front 8 NVMe SFF U.3 or U.2 drive boxes (P27194-B21, P26931-B21, P26932-B21) to total 24 SFF NVMe drives, and up to 32 SFF NVMe drives with one mid 8 NVMe SFF mid-tray drive cage (P39600-B21, P38847-B21). U.3 and U.2 front and mid drive cages cannot mix. - U.3 x1 and x4 drive cages cannot mix. - The 8 LFF chassis cannot be upgraded to 12 LFF front in the field. - 12 LFF or more drives require Max performance fan kit (P14608-B21). - CPU selection is limited 225W (Turbo to 240W) or lower with 4LFF mid-tray selected & DIMM blanks populate empty DIMM slots. |
System Fans Standard - fan types included
|
Standard Features
Processors Up to 2 of the following depending on model. Notes: For more information regarding AMD EPYC processors, please see the following: https://www.amd.com/en/products/epyc | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes: All AMD EPYC processors can support up to 4TB of memory each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chipset No chipset - System on Chip (SoC) design. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
On System Management Chipset HPE iLO 5 ASIC
Read and learn more in the iLO QuickSpecs. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Memory One of the following depending on model | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Notes: - The maximum memory speed is limited by the processor selection. - 3200 MT/s memory SKUs can run the transfer rate of 3200 MT/s at both 1 DIMM and 2 DIMM per channel, except 256 GB LRDIMM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Memory Protection Advanced ECC Advanced ECC uses single device data correction to detect and correct single and all multibit error that occurs within a single DRAM chip. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Expansion Slots
Primary Riser Notes: - Bus width indicates the number of physical electrical lanes running to the connector. - There are 3 types of risers supported on Primary Slot - When supporting Slot1 & Slot2 in below Primary Riser3 scenario, Slot1 & Slot2 combined can support up to 38GB/s bandwidth, due to an AMD CPU limitation. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes: ** Default Slot1 on the Primary Riser3 is empty and not available. It requires P14600-B21 in conjunction with the Primary Riser3 to add additional x16 PCIe Gen4 in slot1. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Secondary Riser: Notes: - Bus Width Indicates the number of physical electrical lanes running to the connector. - There are 3 types of risers support on Secondary Slot | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
Notes: * Default Slot4 on the Secondary Riser3 is empty and not available.It requires P14600-B21 in conjunction with the Secondary Riser3 to add additional x16 PCIe Gen4 in slot4 | ||||||||||||||||||||||||||||||||||||
Tertiary Riser: Notes: - Bus Width Indicates the number of physical electrical lanes running to the connector. - There are 2 types of risers support on Tertiary Slot | ||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
Storage Controllers The Gen10/Gen10 Plus controller naming framework has been updated to simplify identification as depicted below. For a more detailed breakout of the available Gen10/Gen10 Plus Smart Array controllers visit the HPE Smart Array Gen10 Controllers Data Sheet. HPE also launched Tri-Mode controllers which will support NVMe U.3/U.2 drives as wells as SAS/SATA drives. Please see below list for the tri-mode controllers supported on the server. One of the following depending on model | ||||||||||||||||||||||||||||||||||||
NVMe Boot Device
Notes: - NS204i-p will only be supported in Slot 1 of the primary riser. - NS204i-p and Primary Riser HPE DL38X Gen10+ 2x16 Slot 2/3 FIO Kit (P14599-B21) are selected then HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) also must be in the configuration. - Legacy Mode setting (758959-B21) and NS204i-p cannot be selected together. - HPE Universal SATA AIC HHHL M.2 SSD Kit (878783-B21) and NS204i-p cannot be selected together. - When NS204i-p and doublewide GPU are selected together Secondary Riser MUST be selected and doublewide GPU can be maximum of 2. | ||||||||||||||||||||||||||||||||||||
Software RAID - HPE Smart Storage SR100i SR Gen10 Plus SW RAID
| ||||||||||||||||||||||||||||||||||||
Essential RAID Controller
| ||||||||||||||||||||||||||||||||||||
Performance RAID Controller
Notes: Performance RAID Controllers require the HPE Smart Storage Battery (P01366-B21) which is sold separately. | ||||||||||||||||||||||||||||||||||||
Tri-Mode RAID Controller
| ||||||||||||||||||||||||||||||||||||
Internal Storage Devices One of the following depending on model Optical Drive
| ||||||||||||||||||||||||||||||||||||
Hard Drives
| ||||||||||||||||||||||||||||||||||||
Graphics Integrated Video Standard
HPE iLO 5 on system management memory
| ||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
Power Supply
Notes: Available in 94% Power Efficiency.
Notes: Available in 94%. Power Efficiency
Notes: - Available in 96% Power Efficiency - 200-240VAC power input only.
Notes: - Available in 94% Power Efficiency - 277VAC power input.
Notes: - Available in 94% Power Efficiency - -48VDC power input.
Notes: - Available in 96% Power Efficiency. - 200-240VAC power input only.
| ||||||||||||||||||||||||||||||||||||
Notes: - Available in 94% Power Efficiency. - 200-240VAC power input only.
| ||||||||||||||||||||||||||||||||||||
Notes: - Available in 96% Power Efficiency. - 200-240VAC power input only. - Gen10 Plus (and v2) output capped at 1600W maximum, greater than 1600W only feasible on Gen11 systems. | ||||||||||||||||||||||||||||||||||||
HPE Flexible Slot (Flex Slot) Power Supplies share a common electrical and physical design that allows for hot plug, tool-less installation into HPE ProLiant Gen10 Plus Performance Servers. Flex Slot power supplies are certified for high-efficiency operation and offer multiple power output options, allowing users to "right-size" a power supply for specific server configurations. This flexibility helps to reduce power waste, lower overall energy costs, and avoid "trapped" power capacity in the data center. All pre-configured servers ship with a standard 6-foot IEC C-13/C-14 jumper cord (A0K02A). This jumper cord is also included with each standard AC power supply option kit. If a different power cord is required, please check the ProLiant Power Cables web page. To review the power requirements for your selected system, please use the HPE Power Advisor Tool. For information on power specifications and technical content visit HPE Server power supplies. | ||||||||||||||||||||||||||||||||||||
Interfaces
| ||||||||||||||||||||||||||||||||||||
Notes: Not shipping as standard. Available as a CTO option or as a field upgrade (P14611-B21). | ||||||||||||||||||||||||||||||||||||
UEFI Configure and boot your servers securely with industry standard Unified Extensible Firmware Interface (UEFI).
Learn more at http://www.hpe.com/servers/uefi. | ||||||||||||||||||||||||||||||||||||
Operating Systems and Virtualization Software Support for ProLiant Servers
Notes: For more information on Hewlett Packard Enterprise Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server. https://www.hpe.com/us/en/servers/server-operating-systems.html | ||||||||||||||||||||||||||||||||||||
HPE Server UEFI/Legacy ROM Unified Extensible Firmware Interface (UEFI) is an industry standard that provides better manageability and more secured configuration than the legacy ROM while interacting with your server at boot time. HPE ProLiant Gen10 Plus servers have a UEFI Class 2 implementation and support both UEFI Mode (default) and Legacy BIOS Mode. Notes: The UEFI System Utilities tool is analogous to the HPE ROM-Based Setup Utility (RBSU) of legacy BIOS. For more information, please visit http://www.hpe.com/servers/uefi. UEFI enables numerous new capabilities specific to HPE ProLiant servers such as
| ||||||||||||||||||||||||||||||||||||
HPE Server UEFI/Legacy ROM
UEFI Boot Mode only
Notes: For UEFI Boot Mode, boot environment and OS image installations should be configured properly to support UEFI. | ||||||||||||||||||||||||||||||||||||
Industry Standard Compliance
Notes: This support is on the optional Universal Media Bay.
Notes: This support is on the optional Universal Media Bay.
| ||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
Beginning on January 1st, 2024, units sold into the EU, European Economic Area (EEA), the United Kingdom, or Switzerland must include more efficient AC power supplies: 94% for multi-output and 96% for single-output. HPE Flexible Slot power supplies are single-output, and part numbers 865438-B21, P03178-B21, and P44712-B21 are 96% efficient, thus meeting requirements. HPE is on target to fulfil compliant systems ahead of time and will begin enforcing these requirements in advance to satisfy requests with the current power supplies by the set deadline. HPE ProLiant Gen10 servers are compliant with Lot9 requirements. For more information regarding HPE Lot 9 conformance, please visit: https://www.hpe.com/us/en/about/environment/msds-specs-more.html
Notes: For additional technical thermal details regarding ambient temperatures, humidity and features support please visit: http://www.hpe.com/servers/ashrae.
| ||||||||||||||||||||||||||||||||||||
Embedded Management
HPE Integrated Lights-Out (HPE iLO) Monitor your servers for ongoing management, service alerting, reporting and remote management with HPE iLO. Learn more at http://www.hpe.com/info/ilo. | ||||||||||||||||||||||||||||||||||||
Intelligent Provisioning Hassle free server and OS provisioning for 1 or more servers with Intelligent Provisioning. Learn more at http://www.hpe.com/servers/intelligentprovisioning. | ||||||||||||||||||||||||||||||||||||
iLO RESTful API iLO RESTful API is Redfish API conformance and offers simplified server management automation such as configuration and maintenance tasks based on modern industry standards. Learn more at http://www.hpe.com/info/restfulapi. | ||||||||||||||||||||||||||||||||||||
Server Utilities
Active Health System The HPE Active Health System (AHS) is an essential component of the iLO management portfolio that provides continuous, proactive health monitoring of HPE servers. Learn more at http://www.hpe.com/servers/ahs. | ||||||||||||||||||||||||||||||||||||
Active Health System Viewer Use the Active Health System Viewer, a web-based portal, to easily read AHS logs and speed problem resolution with HPE self-repair recommendations, to learn more visit: http://www.hpe.com/servers/ahsv. | ||||||||||||||||||||||||||||||||||||
Smart Update Keep your servers up to date with the HPE Smart Update solution by using Smart Update Manager (SUM) to optimize the firmware and driver updates of the Service Pack for ProLiant (SPP). Learn more at https://www.hpe.com/us/en/servers/smart-update.html . | ||||||||||||||||||||||||||||||||||||
iLO Amplifier Pack Designed for large enterprise and service provider environments with hundreds of HPE servers, the iLO Amplifier Pack is a free, downloadable open virtual application (OVA) that delivers the power to discover, inventory and update Gen8, Gen9 , Gen10 & Gen10 Plus HPE servers at unmatched speed and scale. Use with an iLO Advanced License to unlock full capabilities. Learn more at http://www.hpe.com/servers/iLOamplifierpack. |
HPE iLO Mobile Application Enables the ability to access, deploy, and manage your server anytime from anywhere from select smartphones and mobile devices. For additional information please visit: http://www.hpe.com/info/ilo/mobileapp. |
RESTful Interface Tool RESTful Interface tool (iLOREST) is a single scripting tool to provision using iLO RESTful API to discover and deploy servers at scale. Learn more at http://www.hpe.com/info/resttool. |
Scripting Tools Provision one to many servers using your own scripts to discover and deploy with Scripting Tool (STK) for Windows and Linux or Scripting Tools for Windows PowerShell. Learn more at http://www.hpe.com/servers/powershell. |
HPE OneView Standard HPE OneView Standard can be used for inventory, health monitoring, alerting, and reporting without additional fees. It can monitor multiple HPE server generations. The user interface is similar to the HPE OneView Advanced version, but the software-defined functionality is not available. Learn more at http://www.hpe.com/info/oneview. |
HPE Systems Insight Manager (HPE SIM) Ideal for environments already using HPE SIM, it allows you to monitor the health of your HPE ProLiant Servers and HPE Integrity Servers. Also provides you with basic support for non-HPE servers. HPE SIM also integrates with Smart Update Manager to provide quick and seamless firmware updates. Learn more at http://www.hpe.com/info/hpesim. |
Warranty This product is covered by a global limited warranty and supported by HPE Services and a worldwide network of Hewlett Packard Enterprise Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HPE ServicesHPE Services operational services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
Notes: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have Hewlett Packard Enterprise replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: https://www.hpe.com/us/en/search-results.html?page=1&q=servers%20warranty&autocomplete=0
|
Security
|
|
Optional Features
Server Management
HPE iLO Advanced HPE iLO Advanced licenses offer smart remote functionality without compromise, for all HPE ProLiant servers. The license includes the full integrated remote console, virtual keyboard, video, and mouse (KVM), multi-user collaboration, console record and replay, and GUI-based and scripted virtual media and virtual folders. You can also activate the enhanced security and power management functionality. |
HPE iLO Advanced Premium Security Edition HPE iLO Advanced Premium Security Edition for iLO 5 includes iLO Advanced License plus high-end security modes, unique security capabilities, like Automatic FW recovery; Runtime FW verification, and Secure erase. Learn more about HPE iLO Advanced Premium Security Edition at: http://www.hpe.com/servers/ilopremium. |
HPE GreenLake for Compute Ops Management HPE is intelligently transforming compute management with an intuitive cloud operating experience through HPE GreenLake cloud platform to streamline and secure operations from edge-to-cloud. Automated key lifecycle tasks, for onboarding, updating, managing, and monitoring HPE servers, brings agility and greater efficiencies to wherever compute devices reside via a unified single browser-based interface. Manage single locations or multiple, distributed sites. Keep tens to thousands of servers secure with batch policy controls and automated updates. Compute Ops Management is cloud-native software that is continually updated with new services, features, patches, and fixes. The management application resides in the HPE GreenLake cloud platform (access via https://console.greenlake.hpe.com) and leverages the HPE GreenLake architecture, security, and unified operations. For a complete list of software as-a-service subscription SKUs and more information, visit the HPE GreenLake for Compute Ops Management QuickSpecs: https://www.hpe.com/psnow/doc/a50004263enw For information on supported HPE servers, the complete list can be found here: |
HPE OneView Advanced HPE OneView brings a new level of automation to infrastructure management by taking a template driven approach to provisioning, updating, and integrating compute, storage, and networking infrastructure. It provides full-featured licenses which can be purchased for managing Gen8, Gen9 , Gen10 & Gen10 Plus servers. To learn more visit http://www.hpe.com/info/oneview. |
HPE InfoSight for Servers HPE InfoSight for Servers combines the cloud-based machine learning of InfoSight with the health and performance monitoring of Active Health System (AHS) and iLO to optimize performance and predict and prevent problems. The end result is an intelligent environment that modernizes IT operations and enhances the support experience by predicting and preventing the infrastructure issues that lead to application disruptions, wasted IT staff time and missed business opportunities. Learn more at https://www.hpe.com/servers/infosight |
Rack and Power Infrastructure The story may end with servers, but it starts with the foundation that makes compute go - and business grow. We've reinvented our entire portfolio of rack and power products to make IT infrastructure more secure, more practical, and more efficient. In other words, we have created a stronger, smarter, and simpler infrastructure to help you get the most out of your IT equipment. As an industry leader, Hewlett Packard Enterprise is uniquely positioned to address the key concerns of power, cooling, cable management and system access. HPE G2 Advanced and Enterprise Racks are perfect for the server room or today's modern data center with enhanced airflow and thermal management, flexible cable management, and a 10 year Warranty to support higher density computing. HPE G2 PDUs offer reliable power in flexible form factors that operate at temperatures up to 60°C, include color-coded outlets and load segments and a low-profile design for optimal access to the rack and support for dense rack environments. HPE Uninterruptible Power Systems are cost-effective power protection for any type workload. Some UPSs include options for remote management and extended runtime modules so you're critical dense data center is covered in power outages. HPE KVM Solutions include a console and switches designed to work with your server and IT equipment reliably. We've got a cost-effective KVM switch for your first rack and multiple connection IP switches with remote management and security capabilities to keep your data center rack up and running. Learn more about HPE Racks, KVM, PDUs and UPSs at HPE Rack and Power Infrastructure. |
One Config Simple (SCE) SCE is a guided self-service tool to help sales and non-technical people provide customers with initial configurations in 3 to 5 minutes. You may then send the configuration on for configuration help, or use in your existing ordering processes. If you require "custom" rack configuration or configuration for products not available in SCE, please contact Hewlett Packard Enterprise Customer Business Center or an Authorized Partner for assistance. https://h22174.www2.hpe.com/SimplifiedConfig/Welcome# |
Service and Support
HPE Services No matter where you are in your digital transformation journey, you can count on HPE Services to deliver the expertise you need when, where and how you need it. From planning to deployment, ongoing operations and beyond, our experts can help you realize your digital ambitions.
|
Consulting Services No matter where you are in your journey to hybrid cloud, experts can help you map out your next steps. From determining what workloads should live where, to handling governance and compliance, to managing costs, our experts can help you optimize your operations. https://www.hpe.com/services/consulting
|
HPE Managed Services HPE runs your IT operations, providing services that monitor, operate, and optimize your infrastructure and applications, delivered consistently and globally to give you unified control and let you focus on innovation.
|
Operational services Optimize your entire IT environment and drive innovation. Manage day-to-day IT operational tasks while freeing up valuable time and resources. Meet service-level targets and business objectives with features designed to drive better business outcomes. https://www.hpe.com/services/operational
|
HPE Complete Care Service HPE Complete Care Service is a modular, edge-to-cloud IT environment service designed to help optimize your entire IT environment and achieve agreed upon IT outcomes and business goals through a personalized experience. All delivered by an assigned team of HPE Services experts. HPE Complete Care Service provides:
https://www.hpe.com/services/completecare
|
HPE Tech Care Service HPE Tech Care Service is the operational support service experience for HPE products. The service goes beyond traditional support by providing access to product specific experts, an AI driven digital experience, and general technical guidance to not only reduce risk but constantly search for ways to do things better. HPE Tech Care Service delivers a customer-centric, AI driven, and digitally enabled customer experience to move your business forward. HPE Tech Care Service is available in three response levels. Basic, which provides 9x5 business hour availability and a 2-hour response time. Essential which provides a 15-minute response time 24x7 for most enterprise level customers, and Critical which includes a 6-hour repair commitment where available and outage management response for severity 1 incidents. https://www.hpe.com/services/techcare
|
HPE Lifecycle Services HPE Lifecycle Services provide a variety of options to help maintain your HPE systems and solutions at all stages of the product lifecycle. A few popular examples include:
Notes: To review the list of Lifecycle Services available for your product go to: https://www.hpe.com/services/lifecycle For a list of the most frequently purchased services using service credits, see the HPE Service Credits Menu |
Technical Specifications
System Unit Dimensions
8.75 x 44.54 x 71.2 cm 3.44 x 17.54 x 28 in
8.75 x 44.54 x 74.9 cm 3.44 x 17.54 x 29.5 in Weight (approximate)
15.1 kg / 33.25 lbs with 1 hard drive - Maximum 19.7 kg / 43.50 lbs with 24 hard drives - Minimum 8 SFF chassis with 1x SFF HDD and 7 HDD blanks, 2x Drive Bay blanks, 1x processor including standard heat sink, 1x power supply (plus blank), 1x Smart Array, 1x Riser installed, cables for the above)
- Minimum 17.3 kg / 38.25 lbs with 1 hard drive - Maximum 12 LFF hard drives (no rear drives), 2x processors, 2x power supplies, 1x Smart Array, 2x Risers installed) |
Input Requirements (per power supply) Rated Line Voltage
|
BTU Rating Maximum
|
Power Supply Output (per power supply) Rated Steady-State Power
Maximum Peak Power
|
System Inlet Temperature
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The upper limit and rate of change may be limited by the type and number of options installed. System performance during standard operating support may be reduced if operating with a fan fault or above 30°C (86°F).
For approved hardware configurations, the supported system inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C (95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the URL:http://www.hpe.com/servers/ashrae
For approved hardware configurations, the supported system inlet range is extended to be: 40° to 45°C (104° to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the URL:http://www.hpe.com/servers/ashrae System performance may be reduced if operating in the extended ambient operating range or with a fan fault.
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Relative Humidity
8% to 90% - Relative humidity (Rh), 28°C maximum wet bulb temperature, non-condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. |
Altitude
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
RTC Accuracy
|
Emissions Classification (EMC) - Regulatory Information To view the regulatory information for your product, view the Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center: http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts |
HPE Smart Array For latest information on HPE Smart Array Gen10 Controllers for HPE ProLiant DL, ML and Apollo Servers please refer to their QuickSpecs. (E208i-a,E208i-p,E208e-p,P408i-a,P408i-p,P408e-p,P816i-a) |
Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). The listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. Please have your HPE representative provide information from the HPE EMESC website for further technical details regarding the configurations listed below. | ||||||||||||
|
.
, ,
Táto položka nebola doposiaľ diskutovaná. Ak chcete byť prvý, kliknite na tlačidlo Přidat příspěvek